PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 26, 2009Physiological Measurement308 citations

Arterial blood pressure measurement and pulse wave analysis-–their role in enhancing cardiovascular assessment

View Full Paper
AAAlberto AvolioMBMark ButlinAWA Walsh

Key Result

Combining conventional cuff sphygmomanometry with non-invasive analysis of the peripheral and central arterial pressure waveform improves the quantification of systolic load and cardiovascular assessment.

PICO

P
Population
High blood pressure
I
Intervention / Comparator
Pulse wave analysis and central arterial pressure waveform registration vs Conventional cuff sphygmomanometer alone

Abstract

The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Avolio et al. (2009) conducted a review in High blood pressure. Pulse wave analysis and central arterial pressure waveform registration vs. Conventional cuff sphygmomanometer alone was evaluated. Combining conventional cuff sphygmomanometry with non-invasive analysis of the peripheral and central arterial pressure waveform improves the quantification of systolic load and cardiovascular assessment.

synapsesocial.com/papers/6a16d83cb082e78ad77ba056https://doi.org/10.1088/0967-3334/31/1/r01
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Reliability of a noninvasive device to measure systemic hemodynamics in hemodialysis patients2006 · 6 citations
  2. 2Baroreflex control of muscle sympathetic nerve activity after 120 days of 6° head-down bed rest2000 · 71 citations
  3. 3An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man1993 · 874 citations
  4. 4Comparison of aortic pulse wave velocity measured by three techniques: Complior, SphygmoCor and Arteriograph2008 · 308 citations
  5. 5Evaluation of blood pressure and baroreflex sensitivity by radial artery tonometry versus finger arteriolar photoplethysmography2003 · 17 citations