April 1, 2017Circulation Cardiovascular Imaging159 citations

Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection

View Full Paper
DJDaniel JuneauMGMohammad GolfamSHSamir Hazra

Key Result

18F-FDG PET-CT demonstrated high diagnostic accuracy for CIED infection, with a pooled sensitivity of 87% (95% CI 82%-91%) and specificity of 94% (95% CI 88%-98%).

Study Design

Type

Meta-Analysis

Structured PICO

Do 18F-FDG PET-CT and labeled leukocyte scintigraphy accurately diagnose cardiac implantable electronic device infections?

P
Population
Patients evaluated for cardiac implantable electronic device (CIED) infection (13 studies included in meta-analysis)
I
Intervention
Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography (18F-FDG PET-CT), labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy
O
Outcome
Diagnostic accuracy (sensitivity, specificity, and summary receiver operating characteristic curves) for CIED infectionsurrogate

18F-FDG PET-CT demonstrates high sensitivity and specificity for diagnosing CIED infections and is a robust imaging modality for this condition.

Main Result

Effect estimate: AUC 0.935

Limitations

  • Insufficient data to do a meta-analysis for labeled leukocyte scintigraphy
  • No studies for 67Ga citrate scintigraphy met the inclusion criteria
  • Insufficient data to perform a meta-analysis for labeled leukocyte scintigraphy (LS)
  • No studies for 67Ga citrate scintigraphy met inclusion criteria

Abstract

Background— The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography , labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection. Methods and Results— A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for 18 F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for 67 Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of 18 F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%–91%) and pooled specificity was 94% (95% CI, 88%–98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%. Conclusions— Both 18 F-FDG PET-CT and LS yield high sensitivity, specificity, and accuracy, and thus seem to be useful for the diagnosis of CIED infection, based on robust data for 18 F-FDG PET-CT but limited data for LS. When available, 18 F-FDG PET-CT may be preferred.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Juneau et al. (2017) conducted a meta-analysis in Cardiac implantable electronic device (CIED) infection. 18F-FDG PET-CT and labeled leukocyte scintigraphy was evaluated on Diagnostic accuracy for CIED infection (AUC 0.935). 18F-FDG PET-CT demonstrated high diagnostic accuracy for CIED infection, with a pooled sensitivity of 87% (95% CI 82%-91%) and specificity of 94% (95% CI 88%-98%).