PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 19, 2007Annals of Clinical Biochemistry International Journal of Laboratory Medicine37 citationsOpen Access

Newer cardiac troponin I assays have similar performance to troponin T in patients with end-stage renal disease

PHPeter E. HickmanGKGus KoerbinESEmma Southcott

Key Points

  • This study aims to compare the effectiveness of newer troponin I assays to the traditional troponin T assay in patients with end-stage renal disease undergoing dialysis.
  • Analyzed plasma from 143 patients undergoing haemodialysis or peritoneal dialysis.

Structured PICO

Do newer troponin I assays detect troponin as effectively as troponin T assays in patients with end-stage renal disease on dialysis?

P
Population
143 patients with end-stage renal disease undergoing regular haemodialysis or peritoneal dialysis
I
Intervention
Newer troponin I assays (Abbott Architect, Bayer Centaur and Beckman Accu-TnI)
C
Comparator
Troponin T assay (Roche) and older troponin I assays (DPC Immulite 2000, Abbott AxSYM)
O
Outcome
Detection rate of troponin I and troponin T in plasma samplessurrogate

Newer troponin I assays can detect troponin in ESRD patients on dialysis as effectively as troponin T assays, identifying patients at risk for cardiac events.

Abstract

BACKGROUND: Troponin T is present in the blood of a majority of patients with endstage renal disease (ESRD) undergoing regular dialysis and presence of troponin T is a predictor of adverse outcome in these patients. With several new formulations of troponin I assays available, this study was performed to see whether these newer assays were able to detect troponin I in these patients more effectively than the older assays. METHODS: One hundred and forty-three patients undergoing regular haemodialysis or peritoneal dialysis had plasma collected and troponin T and troponin I measured by a variety of assays. RESULTS: The newer troponin I assays (Abbott Architect, Bayer Centaur and Beckman Accu-TnI) were able to detect troponin I (>75% of samples) as effectively as the Roche assay was able to detect troponin T, while other troponin I assays had a much lower rate of detection of troponin - DPC Immulite 2000 16% and Abbott AxSYM 35%. However, the troponin T assay had more samples detected at concentrations corresponding to an assay CV of 10% (59% of samples) than did the newer troponin I assays (highest on the Bayer Centaur at 37%). CONCLUSIONS: Newer assays demonstrate that troponin I is present in a similar number of samples as is troponin T, in the blood of patients with dialysis-dependent renal failure, and these newer troponin I assays identify patients at risk of experiencing a cardiac event.