PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 1988Archives of Internal Medicine42 citations

The automatic implantable cardioverter-defibrillator. Clinical experience, complications, and follow-up in 25 patients

View Full Paper
JBJ. Borbola

Structured PICO

Does the automatic implantable cardioverter-defibrillator improve survival in high-risk patients with recurrent ventricular tachyarrhythmias?

P
Population
25 patients with recurrent ventricular tachyarrhythmias who had survived one or more cardiac arrests and episodes of syncope, and had received multiple antiarrhythmic drug trials.
I
Intervention
Automatic implantable cardioverter-defibrillator (AICD) implantation
O
Outcome
Survival rate and complicationshard clinical

AICD implantation provides a 100% 12-month arrhythmic death survival rate in high-risk patients with recurrent ventricular tachyarrhythmias, despite significant complication rates.

Abstract

Twenty-five patients with recurrent ventricular tachyarrhythmias underwent implantation of an automatic implantable cardioverter-defibrillator. The mean length of follow-up was 11.9 +/- 10.8 months. Before the implantation, the patients had survived one or more cardiac arrests (mean, 1.7; range, 1 to 4) and episodes of syncope (mean, 2.2; range, 2 to 3) and had received 6.0 +/- 1.0 antiarrhythmic drug trials. The in-hospital complications included death (two patients), reoperation (one patient), intraoperative myocardial infarction (one patient), sensing-failure (one patient), infection (five patients), and pocket seroma (two patients). The posthospital complications included device failure (four patients), device deactivation (one patient), and inappropriate discharge (two patients). The device discharged appropriately in seven patients due to sustained ventricular tachycardia. During electrophysiologic measurements, the energy requirement for successful cardioversion-defibrillation was related to the type of ventricular arrhythmia induced (monomorphic or pleomorphic ventricular tachycardia or fibrillation). Ventricular tachycardia acceleration occurred in ten patients (40%). No significant changes were found in the size of the electrograms or in the cardioversion threshold during early and late follow-up measurements. Life table analysis showed a 12-month survival rate of 86% and an arrhythmic death survival rate of 100%. We confirm the improved rate of survival in this high-risk group of patients, despite significant complications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

J. Borbola (1988) studied this question.

synapsesocial.com/papers/6a1ccc6b732133fe9885e641https://doi.org/10.1001/archinte.148.1.70
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The Automatic Implantable Cardioverter-Defibrillator1988 · 92 citations
  2. 2Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.1985 · 453 citations
  3. 3Long-term outcome with the automatic implantable cardioverter-defibrillator1989 · 724 citations
  4. 4The Automatic Implantable Cardioverter-Defibrillator1992 · 15 citations
  5. 5The Automatic Implantable Cardioverter-Defibrillator: Efficacy, Complications, and Device Failures1986 · 259 citations