June 20, 2018Heart34 citationsOpen Access

Use of routinely captured echocardiographic data in the diagnosis of severe aortic stenosis

View Full Paper
SBSteven M. BradleyKFKatie FoagKMKhua Monteagudo

Structured PICO

Does applying a measure incorporating peak velocity, mean gradient, and dimensionless index improve the diagnostic accuracy of severe aortic stenosis from routine echocardiographic data compared to documented interpretation?

P
Population
213,174 patients who underwent transthoracic echocardiographic imaging within Allina Health between January 2013 and October 2017 (77,067 with complete assessment of the aortic valve)
I
Intervention
Echocardiographic measures for severe aortic stenosis (including aortic valve area, peak velocity, mean gradient, and dimensionless index)
C
Comparator
Documented interpretation of severe aortic stenosis by the echocardiographic reader
O
Outcome
Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of echocardiographic measures for severe aortic stenosis relative to the documented interpretationsurrogate

Using a dimensionless index instead of aortic valve area improves the concordance between quantitative echocardiographic data and documented clinical interpretation of severe aortic stenosis.

Abstract

OBJECTIVE: To determine the implications of applying guideline-recommended definitions of aortic stenosis to echocardiographic data captured in routine clinical care. METHODS: Retrospective observational study of 213 174 patients who underwent transthoracic echocardiographic imaging within Allina Health between January 2013 and October 2017. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of echocardiographic measures for severe aortic stenosis were determined relative to the documented interpretation of severe aortic stenosis. RESULTS: Among 77 067 patients with complete assessment of the aortic valve, 1219 (1.6%) patients were categorised as having severe aortic stenosis by the echocardiographic reader. Relative to the documented interpretation, aortic valve area (AVA) as a measure of severe aortic stenosis had the high sensitivity (94.1%) but a low positive predictive value (37.5%). Aortic valve peak velocity and mean gradient were specific (>99%), but less sensitive (<70%). A measure incorporating peak velocity, mean gradient and dimensionless index (either by velocity time integral or peak velocity ratio) achieved a balance of sensitivity (92%) and specificity (99%) with little detriment in accuracy relative to peak velocity and mean gradient alone (98.9% vs 99.3%). Using all available data, the proportion of patients whose echocardiogram could be assessed for aortic stenosis was 79.8% as compared with 52.7% by documented interpretation alone. CONCLUSION: A measure that used dimensionless index in place of AVA addressed discrepancies between quantitative echocardiographic data and the documented interpretation of severe aortic stenosis. These findings highlight the importance of understanding the limitations of clinical data as it relates to quality improvement efforts and pragmatic research design.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bradley et al. (2018) studied this question.

synapsesocial.com/papers/6a1d2354748c408e6fd31494https://doi.org/10.1136/heartjnl-2018-313269
Ask AI
Helpful
Bookmark
Share
View Full Paper