PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 1, 1990Medical Physics136 citations

EGS4 Monte Carlo determination of the beta dose kernel in water

View Full Paper
DSDouglas J. SimpkinTMT. Rockwell Mackie

Key Points

Key points are not available for this paper at this time.

Abstract

The EGS4 Monte Carlo code has been used to simulate the emission and energy deposition in H 2 O about point sources of monoenergetic electrons and radionuclides of potential use in radioimmunotherapy. The radiations studied were 0.05, 0.1, 0.5, 1.0, 2.0, and 3.0 MeV monoenergetic electrons and 32 P, 67 Cu, 90 Y, 105 Rh, 131 I, 153 Sm, 186 Re, and 188 Re β particles and conversion and Auger electrons. Ten batches of 10 000 electrons (or 10 000 radionuclide decays) each were started isotropically at a point in an infinite homogeneous H 2 O phantom. The parameter–reduced electron–step transport algorithm (PRESTA) version of the EGS4 Monte Carlo code was used to follow these and their progeny, scoring the energy deposited in thin spherical shells. The scaled dose kernels are calculated and compared to kernels available in the literature. These previously published kernels either completely ignore secondary electrons or are based on a Monte Carlo code which improperly sampled the Landau energy straggling distribution.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Simpkin et al. (1990) studied this question.

synapsesocial.com/papers/6a205858e9ca693ff1e730d8https://doi.org/10.1118/1.596565
Ask AI
Helpful
Bookmark
Share
View Full Paper