PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 1, 2001Experimental Physiology82 citationsOpen Access

Functional properties and responses to ischaemia‐reperfusion in Langendorff perfused mouse heart

View Full Paper
JHJohn P. HeadrickJPJason N. PeartBHBen Hack

Key Result

The buffer perfused isovolumically contracting mouse heart model is more reliable and yields higher post-ischaemic recoveries than the apicobasal model.

Structured PICO

P
Population
C57/BL6 mouse hearts subjected to 10-30 min global ischaemia to assess functional properties and responses to ischaemia-reperfusion.
I
Intervention
Isovolumic ventricular balloon model with 10-30 min global ischemia and 40 min reperfusion
C
Comparator
Apicobasal displacement model
O
Outcome
Post-ischemic recovery of developed pressure and contractility (+dP/dt)surrogate

The buffer perfused isovolumically contracting mouse heart model is more reliable in assessing ischemic responses than the commonly employed apicobasal model.

Main Result

Absolute Event Rate: 82% vs 80%

Abstract

Despite minimal model characterisation Langendorff perfused murine hearts are increasingly employed in cardiovascular research, and particularly in studies of myocardial ischaemia and reperfusion. Reported contractility remains poor and ischaemic recoveries variable. We characterised function in C57/BL6 mouse hearts using a ventricular balloon or apicobasal displacement and assessed responses to 10-30 min global ischaemia. We examined the functional effects of pacing, ventricular balloon design, perfusate filtration, Ca(2+) and temperature. Contractility was high in isovolumically functioning mouse hearts (measured as the change in pressure with time (+dP/dt), 6000-7000 mmHg s(-1)) and was optimal at a heart rate of approximately 420 beats min(-1), with the vasculature sub-maximally dilated, and the cellular energy state high. Post-ischaemic recovery (after 40 min reperfusion) was related to the ischaemic duration: developed pressure recovered by 82 +/- 5 %, 73 +/- 4 %, 68 +/- 3 %, 57 +/- 2 % and 41 +/- 5 % after 10, 15, 20, 25 and 30 min ischaemia, respectively. Ventricular compliance and elastance were both reduced post-ischaemia. Post-ischaemic recoveries were lower in the apicobasal model (80 +/- 4 %, 58 +/- 7 %, 40 +/- 3 %, 32 +/- 7 % and 25 +/- 5 %) despite greater reflow and lower metabolic rate (pre-ischaemic myocardial O(2) consumption (V(O2,myo)) 127 +/- 15 vs. 198 +/- 17 microl O(2) min(-1) g(-1)), contracture, enzyme and purine efflux. Electrical pacing slowed recovery in both models, small ventricular balloons (unpressurised volumes < 50-60 microl) artificially depressed ventricular function and recovery from ischaemia, and failure to filter the perfusion fluid to < 0.45 microm depressed pre- and post-ischaemic function. With attention to these various experimental factors, the buffer perfused isovolumically contracting mouse heart is shown to be stable and highly energized, and to possess a high level of contractility. The isovolumic model is more reliable in assessing ischaemic responses than the commonly employed apicobasal model.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Headrick et al. (2001) studied Myocardial ischaemia and reperfusion. Isovolumic ventricular balloon model vs. Apicobasal displacement model was evaluated on Post-ischaemic recovery of developed pressure after 10 min ischaemia. The buffer perfused isovolumically contracting mouse heart model is more reliable and yields higher post-ischaemic recoveries than the apicobasal model.

synapsesocial.com/papers/6a22076e2221fd35d14929cchttps://doi.org/10.1111/j.1469-445x.2001.tb00035.x
Ask AI
Helpful
Bookmark
Share
View Full Paper