PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 1, 1996European Journal of Morphology4 citations

Optimization of Left Ventricular Fibre Orientation of the Normal Heart for Homogeneous Sarcomere Length During Ejection

View Full Paper
JRJ.M. RijckenTATheo ArtsPBPeter H. M. Bovendeerd

Structured PICO

P
Population
Finite element model of left ventricular wall mechanics (equatorial region of the normal heart)
I
Intervention
Optimization of the transmural course of fibre angle (slope alone, and slope plus intercept)
O
Outcome
Variance of sarcomere length (homogeneity in mechanical loading) at a cavity pressure of 15 kPasurrogate

Computational modeling demonstrates that optimizing the transmural course of left ventricular fibre angles yields physiological values and improves homogeneity of mechanical load during ejection.

Abstract

UNLABELLED: During the ejection phase of the cardiac cycle, left ventricular muscle fibres shorten while generating force. It was hypothesized that fibres are oriented in the wall such that the amount of shortening is the same for all fibres. We evaluated this hypothesis for the equatorial region of the left ventricle. In a finite element model of left ventricular wall mechanics fibre orientation was quantified by a helix angle which varied linearly from the inner to the outer wall. Fibre length was characterized by sarcomere length, set at 1.95 microns everywhere in the passive state of 0 transmural pressure. For a cavity pressure of 15 kPa, considered representative for ejection, inhomogeneity in mechanical loading was expressed by the variance of the sarcomere length. The variance was minimized by adapting the transmural course of fibre angle. First, only the slope was optimized and in a second optimization this was done for both slope and intercept. Optimal helix fibre angles were 69.6 degrees endocardially, 0 degree at the middle of the wall and -69.6 degrees epicardially for the first optimization and 78.2 degrees, 20.7 degrees and, -36.7 degrees respectively for the second. Sarcomere length changed from 1.95 to 1.975 +/- 0.012 and 1.981 +/- 0.004 microns (mean +/- SD) respectively. CONCLUSION: After optimization calculated helix fibre angles were in the physiological range. Describing the transmural course of fibre angle with slope and intercept significantly improved homogeneity in mechanical load.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Rijcken et al. (1996) studied this question.

synapsesocial.com/papers/6a22f67bb171aa1b1ecac863https://doi.org/10.1076/ejom.34.1.39.13154
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Optimizing ventricular fibers: uniform strain or stress, but not ATP consumption, leads to high efficiency2002 · 142 citations
  2. 2Ventricular fiber optimization utilizing the branching structure2015 · 35 citations
  3. 3Normal long axis function1999 · 217 citations
  4. 4Engineering Mechanics for Successive States in Canine Left Ventricular Myocardium1973 · 221 citations
  5. 5A computer study of the left ventricular performance based on fiber structure, sarcomere dynamics, and transmural electrical propagation velocity.1984 · 140 citations