3D Quantification of Wall Shear Stress and Oscillatory Shear Index Using a Finite-Element Method in 3D CINE PC-MRI Data of the Thoracic Aorta

View Full Paper
JSJulio SoteloJUJesús UrbinaIVIsrael Valverde

Key Result

A novel 3D finite-element method for 3D-CINE PC-MRI provided more accurate wall shear stress estimates than 2D analysis by accounting for longitudinal velocity gradients.

Structured PICO

Does a 3D finite-element method improve the accuracy of WSS and OSI quantification from 3D-CINE PC-MRI compared to 2D methods?

P
Population
16 healthy volunteers and 2 patients, along with synthetic and aortic phantoms, evaluated using a novel 3D finite-element method for WSS and OSI quantification.
E
Exposure
3D finite-element method for quantification of Wall Shear Stress (WSS) and Oscillatory Shear Index (OSI) from 3D-CINE PC-MRI
C
Comparator
2D analysis not considering out-of-plane velocity gradients
O
Outcome
Accuracy of WSS and OSI estimatessurrogate

A novel 3D finite-element method for quantifying WSS and OSI from 3D-CINE PC-MRI improves accuracy over 2D methods by accounting for longitudinal velocity gradients.

Limitations

  • OSI values show a greater dispersion than WSS, which is strongly dependent on the PC-MRI resolution.

Abstract

Several 2D methods have been proposed to estimate WSS and OSI from PC-MRI, neglecting the longitudinal velocity gradients that typically arise in cardiovascular flow, particularly on vessel geometries whose cross section and centerline orientation strongly vary in the axial direction. Thus, the contribution of longitudinal velocity gradients remains understudied. In this work, we propose a 3D finite-element method for the quantification of WSS and OSI from 3D-CINE PC-MRI that accounts for both in-plane and longitudinal velocity gradients. We demonstrate the convergence and robustness of the method on cylindrical geometries using a synthetic phantom based on the Poiseuille flow equation. We also show that, in the presence of noise, the method is both stable and accurate. Using computational fluid dynamics simulations, we show that the proposed 3D method results in more accurate WSS estimates than those obtained from a 2D analysis not considering out-of-plane velocity gradients. Further, we conclude that for irregular geometries the accurate prediction of WSS requires the consideration of longitudinal gradients in the velocity field. Additionally, we compute 3D maps of WSS and OSI for 3D-CINE PC-MRI data sets from an aortic phantom and sixteen healthy volunteers and two patients. The OSI values show a greater dispersion than WSS, which is strongly dependent on the PC-MRI resolution. We envision that the proposed 3D method will improve the estimation of WSS and OSI from 3D-CINE PC-MRI images, allowing for more accurate estimates in vessels with pathologies that induce high longitudinal velocity gradients, such as coarctations and aneurisms.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sotelo et al. (2016) studied Healthy volunteers and patients undergoing thoracic aorta imaging (n=18). 3D finite-element method for 3D-CINE PC-MRI vs. 2D analysis was evaluated on Accuracy of WSS and OSI estimates. A novel 3D finite-element method for 3D-CINE PC-MRI provided more accurate wall shear stress estimates than 2D analysis by accounting for longitudinal velocity gradients.

synapsesocial.com/papers/6a22fc1cc650520b07cb1d35https://doi.org/10.1109/tmi.2016.2517406