August 15, 2008EP Europace59 citationsOpen Access

Longevity of implantable cardioverter-defibrillators: implications for clinical practice and health care systems

View Full Paper
MBM. BiffiMZMatteo ZiacchiMBMatteo Bertini

Structured PICO

Does Medtronic implantable cardioverter-defibrillators improve device longevity compared to Guidant and St Jude Medical devices in patients requiring ICDs?

P
Population
153 patients who received an implantable cardioverter-defibrillator (ICD) between January 1, 2000, and December 31, 2002 (80 single-chamber, 59 double-chamber, 14 CRT-D). Patients who died or were transplanted before battery exhaustion were excluded from the longevity analysis.
I
Intervention
Medtronic (MDT) implantable cardioverter-defibrillators
C
Comparator
Guidant (GDT) and St Jude Medical (SJM) implantable cardioverter-defibrillators
O
Outcome
Device longevity (time to battery exhaustion requiring replacement)

ICD battery longevity varies significantly among manufacturers, which directly impacts the cost-effectiveness and cost per month of treatment.

Abstract

AIMS: Comparative studies on the longevity of implantable cardioverter-defibrillators (ICDs) among different manufacturers have never been reported. Longevity of ICD devices implanted from 1 January 2000 to 31 December 2002 was prospectively investigated according to their type and manufacturer. METHODS AND RESULTS: Longevity of single-chamber (SC), double-chamber (DC), and biventricular (CRT-D) ICDs from Medtronic (MDT), Guidant (GDT), and St Jude Medical (SJM) was measured in all the patients who required device replacement. The observation follow-up ended on 31 December 2007; patients who died prematurely or were transplanted before battery exhaustion were excluded from the analysis. Factors associated with longevity (number of delivered shocks, pacing activity) were researched. One hundred and fifty-three patients received an ICD in the abovementioned period. Six underwent heart transplantation, and 23 died before device replacement; 80 had an SC device, 59 had DC device, and 14 had CRT-D device. Longevity of MDT was superior to GDT and SJM, replacement rates being, respectively, 42%, 95.3%, and 97.2%. Only MDT manufacturers and SC type were associated with greater ICD longevity. Longevity had an impact on the cost/month of treatment of replaced ICDs. CONCLUSION: Battery longevity is significantly different among manufacturers. ICD cost is strictly dependent on device longevity, whereas device up-front cost is of limited clinical meaning. Appropriate assessment of cost-effectiveness should be based on ICD longevity in the real-life scenario.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Biffi et al. (2008) studied this question.

synapsesocial.com/papers/6a230a883b0298f8f757fe0dhttps://doi.org/10.1093/europace/eun240
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Longevity of implantable cardioverter defibrillators: a comparison among manufacturers and over time2015 · 48 citations
  2. 2Analysis of Implantable Defibrillator Longevity Under Clinical Circumstances: Implications for Device Selection2009 · 29 citations
  3. 3Real‐World Data on the Lifespan of Implantable Cardioverter‐Defibrillators Depending on Manufacturers and the Amount of Ventricular Pacing2012 · 71 citations
  4. 4“Real life” longevity of implantable cardioverter‐defibrillator devices2017 · 44 citations
  5. 5Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators2013 · 48 citations