PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 1, 1993European Heart Journal126 citations

Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dipyridamole echocardiography

View Full Paper
EPEugenio PicanoAPAlessandro PingitoreUCUmberto Conti

Key Result

The addition of atropine to dipyridamole echocardiography increased the sensitivity for detecting coronary artery disease from 72% to 85% (P<0.01) with no loss in specificity.

Study Design

Type

Cross-Sectional (n=321)

Structured PICO

Does the addition of atropine to dipyridamole echocardiography improve the sensitivity for detecting coronary artery disease in patients referred for echo testing?

P
Population
321 patients (mean age 58 years) referred for echocardiography testing, including a subset of 178 who underwent coronary catheterization to assess diagnostic accuracy.
E
Exposure
Dipyridamole-atropine echo test (DETA): Atropine (0.25 mg intravenously, repeated every min up to a maximum of 1 mg) added 3 min after the end of dipyridamole infusion in patients with an initially negative dipyridamole echocardiography test.
C
Comparator
Dipyridamole echocardiography test (DET) alone.
O
Outcome
Sensitivity and specificity for the detection of significant coronary artery disease (≥ 50% luminal reduction in at least one major coronary vessel by quantitative coronary arteriography).surrogate

The addition of atropine to dipyridamole echocardiography safely increases the sensitivity for detecting significant coronary artery disease without compromising specificity.

Main Result

Absolute Event Rate: 85% vs 72%

p-value: p=<0.01

Abstract

Dipyridamole echocardiography test (DET) has gained acceptance due to its safety, feasibility, diagnostic accuracy and prognostic power. The main limitation of the test is a less than ideal sensitivity in some patient subsets, such as those with limited coronary artery disease. Atropine with dipyridamole might theoretically combine to become a synergistic ischaemic stress test, by increasing myocardial oxygen demand through chronotropic stress and by reducing flow supply through a shortening of the diastolic interval under maximal coronary vasodilation. The aim of this study was to assess the effects of the addition of atropine to DET. Three hundred and twenty-one patients (age=58±9 years), referred for testing in the echo lab, were initially studied by DET. Of these, 151 were stopped during or within the 2 min following dipyridamole infusion because of achievement of a predetermined end-point: obvious echocardiographic positivity (n = 137), severe chest pain (n = 3), diagnostic ST segment changes (n = 7) or limited side effects (n = 4). In another three cases, atropine was not given due to a history of glaucoma or severe prostatic hypertrophy. In the remaining 167 patients with a negative DET test, atropine (0.25 mg intravenously, repeated every min up to a maximum of 1 mg, if necessary) was added, starting 3 min after the end of the dipyridamole infusion. The dipyridamole-atropine echo test (DETA) was positive in 32 and negative in 135 patients, and no major side effects occurred in any patient. The peak heart rate was significantly higher during DETA than with DET alone (108±16 vs 86±14 beats . min−1; P<0.0001). In the subset of 178 patients who were studied while not taking antianginal therapy, who had no prior myocardial infarction or revascularization procedure and who underwent coronary catheterization, independently of the test results, coronary angiography showed normal coronary arteries in 48 patients and significant coronary artery disease (CAD) (≥ 50% luminal reduction in at least one major coronary vessel by quantitative coronary arteriography) in 130 patients—with single-, double- and triple-vessel disease in 56, 47 and 27 patients, respectively. The sensitivity was 96/130 for DET and 110/130 for DETA (72 vs 85%, P<0.01) while the specflcity was 96% and 92% (P=ns), respectively. The addition of atropine to dipyridamole, which causes further chronotropic stress to the myocardium already challenged by flow maldistribution, is well tolerated and safe, and increases the sensitivity of the test for the detection of coronary artery disease with no loss in specificity.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Picano et al. (1993) conducted a cross-sectional in Coronary artery disease (n=321). Addition of atropine to dipyridamole echocardiography vs. Dipyridamole echocardiography alone was evaluated on Sensitivity for detection of coronary artery disease (p=<0.01). The addition of atropine to dipyridamole echocardiography increased the sensitivity for detecting coronary artery disease from 72% to 85% (P<0.01) with no loss in specificity.

synapsesocial.com/papers/6a2820baa7d437da23177691https://doi.org/10.1093/eurheartj/14.9.1216