Increasing Peripheral Artery Intima Thickness From Childhood to Seniority

View Full Paper
WOWalter OsikaFDFrida DangardtJGJulia Grönros

Structured PICO

Can very high-resolution ultrasound biomicroscopy accurately measure peripheral artery intima thickness and detect age-related or disease-related changes?

P
Population
90 healthy subjects (aged between 10 and 90 years), 18 patients undergoing colectomy (providing mesenteric artery specimens), and an unspecified number of patients with peripheral artery disease.
I
Intervention
Very high-resolution ultrasound biomicroscopy (55 MHz)
C
Comparator
Morphometry (for ex vivo mesenteric artery specimens)
O
Outcome
Intima thickness (IT) and intima-media thickness of radial and anterior tibial arteriessurrogate

Very high-resolution ultrasound biomicroscopy is feasible for measuring peripheral artery intima thickness, demonstrating that intima thickness progresses with age and is increased in peripheral artery disease.

Abstract

BACKGROUND: Using new, very high-resolution ultrasound biomicroscopy, we examined the thickness of artificial layers of silicone and intima thickness (IT) of radial and anterior tibial arteries in healthy subjects and in patients with vascular disease. METHODS AND RESULTS: Silicone layers of varying thicknesses and mesenteric artery specimens obtained from 18 patients undergoing colectomy were measured by both ultrasound biomicroscopy (55 MHz) and morphometry. There was high correlation (r>0.9; P<0.0001) between IT and intima area versus ultrasound biomicroscopy. In 90 healthy subjects (aged between 10 and 90 years), radial and anterior tibial arterial IT and intima-media thickness were measured, as was carotid intima-media thickness in 56 of these subjects. Age was strongly related with both media thickness and IT of both peripheral arteries. Correlations were found between carotid intima-media thickness and both radial and anterior tibial IT/intima-media thickness (r=0.44 to 0.53; P<0.0001). The IT-to-lumen diameter ratio increased with age and was larger at all ages in the anterior tibial artery (0.067+/-0.034) versus the radial artery (0.036+/-0.012; P<0.0001). A thicker radial intimal layer was found in patients with peripheral artery disease. CONCLUSION: This study is the first to our knowledge in humans to show the feasibility of measuring IT of the radial and anterior tibial arteries using very high-resolution ultrasound. IT progresses with age, and the IT-to-lumen diameter ratio is largest in the arteries of the foot. Assessment of IT by ultrasound biomicroscopy may aid in detecting early peripheral vascular abnormalities.