PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 1997Stroke124 citations

Reproducibility of Ultrasonographically Determined Intima-Media Thickness Is Dependent on Arterial Wall Thickness

View Full Paper
ESEva Stensland-BuggeKBKaare Harald BønaaOJOddmund Joakimsen

Structured PICO

Is B-mode ultrasonography reproducible for measuring carotid intima-media thickness, and what factors affect measurement error?

P
Population
111 participants from the Tromsø Study (out of 6676 total participants) who underwent a second ultrasound scan
I
Intervention
B-mode ultrasonographic measurements of intima-media thickness (IMT) in various segments of the right carotid artery
O
Outcome
Reproducibility of IMT measurements (between-observer and within-observer absolute differences)surrogate

B-mode ultrasound provides reproducible estimates of carotid IMT, though measurement error increases proportionally with the level of IMT.

Abstract

BACKGROUND AND PURPOSE: We compared the reproducibility of B-mode ultrasonographic measurements of intima-media thickness (IMT) in various segments of the right carotid artery and examined whether measurement error was associated with IMT or cardiovascular risk factor levels. METHODS: In 1994/1995 a total of 6676 participants in the Tromsø Study underwent ultrasound examination of common carotid artery IMT. Reproducibility of measurements was assessed by inviting 111 participants to a second ultrasound scan within 3 weeks of the first scan. On each occasion the subjects were examined by three sonographers. RESULTS: The mean between-observer absolute differences in IMT in the far wall of the bifurcation and the near and far walls of the common carotid-artery were 0.15, 0.10, and 0.08 mm, respectively. The corresponding within-observer differences were 0.15, 0.10, and 0.06 mm, respectively. Approximately 70% to 80% of total measurement variability was due to differences among sonographers; the rest was attributable to within-reader variability. Measurement error increased significantly with increasing IMT: the increase was more than twofold over the range of measurements. Cardiovascular risk factor levels were not associated with measurement variability when we controlled for IMT. CONCLUSIONS: We conclude that B-mode ultrasound provides reproducible estimates of the IMT in both the near and far walls of the carotid artery. Although measurement error is generally small, it increases proportionally with the level of IMT.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Stensland-Bugge et al. (1997) studied this question.

synapsesocial.com/papers/6a70c7fc31a3df82432905cchttps://doi.org/10.1161/01.str.28.10.1972
Ask AI
Helpful
Bookmark
Share
View Full Paper