Objective To evaluate the concordance of four anti-dsDNA antibody detection methods—Crithidia luciliae indirect immunofluorescence test (CLIFT), enzyme-linked immunosorbent assay (ELISA), acridine ester direct chemiluminescence immunoassay (CLIA), and digital liquid chip method (DLCM)—and to assess their diagnostic efficacy in systemic lupus erythematosus (SLE) patients. Methods A total of 285 serum samples were collected, including 170 SLE patients, 39 with non-SLE autoimmune diseases (AIDs), 28 with non-AIDs, and 48 undiagnosed cases. The concordance and diagnostic performance of anti-dsDNA antibody methods were analyzed. Results The diagnostic performance showed that DLCM exhibited the highest sensitivity (86.87%), while CLIA demonstrated the highest specificity (94.03%). The area under the receiver operating characteristic (ROC) curve (AUC) was ranked as CLIFT 0.6, P 0.8, P < 0.001). Conclusion CLIFT, ELISA, CLIA, and DLCM all showed impressive diagnostic efficacy in detecting anti-dsDNA antibodies. CLIFT shows a strong correlation with SLE activity and lupus nephritis. DLCM, a relatively new method, also showed excellent performance and could be integrated into clinical laboratory workflows for anti-dsDNA antibody testing.
Gao et al. (Sat,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: