Parallel inverter systems constitute the fundamental units of AC microgrids and distributed renewable energy generation systems, wherein accurate power sharing among units represents a critical challenge for stable operation. Conventional droop control fails to share the harmonic power in proportionality to the capacity of inverters due to disparities on line impedance, leading to circulating currents, degraded power quality, and reduced system load capability. To address these issues, this paper proposes a harmonic power-sharing control strategy based on perturbative virtual impedance injection. Under the premise that fundamental power sharing according to capacity ratios has been ensured, the strategy first converts the harmonic power information of each inverter into a small-signal perturbation, which is injected into the virtual impedance of its fundamental control loop. Subsequently, by detecting the resulting variations in fundamental power coefficients induced by this perturbation, a closed-loop feedback is constructed to adaptively adjust the virtual impedance value of each inverter at harmonic frequencies. This adjustment enables the automatic matching of the harmonic power distribution ratio to the inverter capacity ratio, ultimately achieving precise harmonic power sharing. The proposed strategy operates without requiring inter-unit communication links or sampling the voltage at the common coupling point, relying solely on local information, thereby enhancing system reliability. Finally, the effectiveness of the proposed control strategy in achieving harmonic power sharing under conditions of line impedance mismatch is validated through an RT-LAB hardware-in-the-loop platform.
Chang et al. (Sat,) studied this question.