Key points are not available for this paper at this time.
Based on these simulations the authors postulate that lateral saccular aneurysms located on more curved arteries are subjected to higher hemodynamic stresses. Saccular aneurysms with wider necks have larger impact zones. The large impact zone at the distal side of the aneurysm neck correlates well with other findings, implicating this zone as the most likely site of aneurysm growth or regrowth of treated lesions. To protect against high hemodynamic stresses, protection of the distal side of the aneurysm neck from flow impingement is critical.
Hoi et al. (Fri,) studied this question.