Microvolt T-wave alternans testing did not predict arrhythmic events or mortality among patients with heart failure and systolic dysfunction (HR 1.24; 95% CI 0.60-2.59; P=0.56).
RCT (n=490)
blinded readers
randomized
Yes
Does microvolt T-wave alternans testing predict arrhythmic events or mortality in patients with heart failure and systolic dysfunction?
Microvolt T-wave alternans testing does not predict arrhythmic events or mortality in patients with heart failure and left ventricular systolic dysfunction, suggesting it is not useful for guiding ICD therapy in this population.
Effect estimate: HR 1.24 (95% CI 0.60 to 2.59)
p-value: p=0.56
BACKGROUND: Sudden cardiac death remains a leading cause of mortality despite advances in medical treatment for the prevention of ischemic heart disease and heart failure. Recent studies showed a benefit of implantable cardioverter defibrillator implantation, but appropriate shocks for ventricular tachyarrhythmias were noted only in a minority of patients during 4 to 5 years of follow-up. Accordingly, better risk stratification is needed to optimize patient selection. In this regard, microvolt T-wave alternans (TWA) has emerged as a potentially useful measure of arrhythmia vulnerability, but it has not been evaluated previously in a prospective, randomized trial of implantable cardioverter defibrillator therapy. METHODS AND RESULTS: This investigation was a prospective substudy of the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) that included 490 patients at 37 clinical sites. TWA tests were classified by blinded readers as positive (37%), negative (22%), or indeterminate (41%) by standard criteria. The composite primary end point was the first occurrence of any of the following events: sudden cardiac death, sustained ventricular tachycardia/fibrillation, or appropriate implantable cardioverter defibrillator discharge. During a median follow-up of 30 months, no significant differences in event rates were found between TWA-positive or -negative patients (hazard ratio 1.24, 95% confidence interval 0.60 to 2.59, P=0.56) or TWA-negative and nonnegative (positive and indeterminate) subjects (hazard ratio 1.28, 95% confidence interval 0.65 to 2.53, P=0.46). Similar results were obtained with the inclusion or exclusion of patients randomized to amiodarone in the analyses. CONCLUSIONS: TWA testing did not predict arrhythmic events or mortality in SCD-HeFT, although a small reduction in events (20% to 25%) among TWA-negative patients cannot be excluded given the sample size of this study. Accordingly, these results suggest that TWA is not useful as an aid in clinical decision making on implantable cardioverter defibrillator therapy among patients with heart failure and left ventricular systolic dysfunction.
Gold et al. (Tue,) は心不全と収縮機能障害に関するランダム化比較試験(n=490)を実施した。マイクロボルトT波交互作用(TWA)陽性 versus TWA陰性は、突然死の初回発生、持続的心室頻拍/震え、または適切な植込み型除細動器の放電において評価された(HR 1.24、95% CI 0.60から2.59、p=0.56)。心不全および収縮機能障害の患者において、マイクロボルトT波交互作用検査は不整脈イベントや死亡を予測しなかった(HR 1.24; 95% CI 0.60-2.59; P=0.56).