PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 24, 2016Data123 citationsOpen Access

Description of a Database Containing Wrist PPG Signals Recorded during Physical Exercise with Both Accelerometer and Gyroscope Measures of Motion

DJDelaram JarchiACAlexander J. Casson

Key Result

A newly described public database provides wrist PPG, chest ECG, 3-axis accelerometer, and 3-axis gyroscope signals during physical exercise to facilitate motion artifact removal algorithms.

Structured PICO

P
Population
Subjects undergoing physical exercise (walking, running, easy bike riding, and hard bike riding)
I
Intervention
Wrist photoplethysmography (PPG) recorded alongside 3-axis low-noise accelerometer, 3-axis wide-range accelerometer, and 3-axis gyroscope data
C
Comparator
Chest electrocardiography (ECG) as a reference
O
Outcome
Heart rate and heart rate variability extractionsurrogate

A new public database incorporating wrist PPG, ECG, and gyroscopic motion data during exercise will facilitate the development of improved algorithms for motion artifact removal and accurate heart rate monitoring.

Abstract

Wearable heart rate sensors such as those found in smartwatches are commonly based upon Photoplethysmography (PPG) which shines a light into the wrist and measures the amount of light reflected back. This method works well for stationary subjects, but in exercise situations, PPG signals are heavily corrupted by motion artifacts. The presence of these artifacts necessitates the creation of signal processing algorithms for removing the motion interference and allowing the true heart related information to be extracted from the PPG trace during exercise. Here, we describe a new publicly available database of PPG signals collected during exercise for the creation and validation of signal processing algorithms extracting heart rate and heart rate variability from PPG signals. PPG signals from the wrist are recorded together with chest electrocardiography (ECG) to allow a reference/comparison heart rate to be found, and the temporal alignment between the two signal sets is estimated from the signal timestamps. The new database differs from previously available public databases because it includes wrist PPG recorded during walking, running, easy bike riding and hard bike riding. It also provides estimates of the wrist movement recorded using a 3-axis low-noise accelerometer, a 3-axis wide-range accelerometer, and a 3-axis gyroscope. The inclusion of gyroscopic information allows, for the first time, separation of acceleration due to gravity and acceleration due to true motion of the sensor. The hypothesis is that the improved motion information provided could assist in the development of algorithms with better PPG motion artifact removal performance.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jarchi et al. (2016) studied this question. Wrist PPG with accelerometer and gyroscope vs. Chest ECG was evaluated. A newly described public database provides wrist PPG, chest ECG, 3-axis accelerometer, and 3-axis gyroscope signals during physical exercise to facilitate motion artifact removal algorithms.

synapsesocial.com/papers/6a1ad58e739ab56a9086078bhttps://doi.org/10.3390/data2010001
Ask AI
Helpful
Bookmark
Share
View Full Paper