PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 1, 20156 citations

Performance evaluation of ECG compression techniques

View Full Paper
GSGoutam Kumar SahooSASamit AriSPSarat Kumar Patra

Key Result

An EMD-based ECG compression technique achieved an average compression ratio of 23.74:1 and a percent root mean square difference of 1.49, outperforming earlier methods.

Structured PICO

Does an EMD-based compression technique improve compression ratio and PRD for ECG signals compared to earlier methods?

P
Population
48 ECG records from the MIT/BIH arrhythmia database used to evaluate a new ECG compression technique.
I
Intervention
A new compression and reconstruction technique based on Empirical Mode Decomposition (EMD), downsampling, discrete cosine transform (DCT), window filtering, and Huffman encoding
C
Comparator
Earlier compression methods
O
Outcome
Compression Ratio (CR) and Percent Root mean square Difference (PRD)surrogate

The proposed EMD-based ECG compression technique achieves a high compression ratio of 23.74:1 with a low PRD of 1.49, outperforming earlier methods.

Abstract

Compression of bulky electrocardiogram (ECG) signal is a common requirement for most of the computerized applications. In this paper, a new compression and reconstruction technique based on Empirical Mode Decomposition (EMD) is proposed. The performance evaluation of the proposed technique is based on comparisons of Compression Ratio (CR) and Percent Root mean square Difference (PRD). The compression method consists of mainly five stages: EMD based signal decomposition, downsampling, discrete cosine transform (DCT), window filtering and Huffman encoding. The ECG signal reconstruction method follows the compression process in reverse order. The proposed algorithm is validated by testing on 48 ECG records available in MIT/BIH arrhythmia database. The compression efficiency is evaluated and the average values of CR and PRD are found to be 23.74:1 and 1.49, respectively. The experimental result shows that the proposed method achieves better compression ratio along with better PRD compared to earlier methods.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sahoo et al. (2015) studied Arrhythmia (n=48). EMD-based compression and reconstruction technique vs. Earlier methods was evaluated on Compression Ratio (CR) and Percent Root mean square Difference (PRD). An EMD-based ECG compression technique achieved an average compression ratio of 23.74:1 and a percent root mean square difference of 1.49, outperforming earlier methods.

synapsesocial.com/papers/6a21a25896850e9b858ba4ddhttps://doi.org/10.1109/icecct.2015.7226202
Ask AI
Helpful
Bookmark
Share
View Full Paper