January 1, 2007Optics Express298 citationsOpen Access

A high-resolution silicon-on-insulator arrayed waveguide grating microspectrometer with sub-micrometer aperture waveguides

View Full Paper
PCPavel ChebenJSJens H. SchmidADA. Delâge

Key Points

Key points are not available for this paper at this time.

Abstract

We demonstrate a 50-channel high-resolution arrayed waveguide grating microspectrometer with a 0.2 nm channel spacing on a silicon-on-insulator (SOI) platform. The chip size is 8 mm x 8 mm. High channel density and spectral resolution are achieved using high aspect ratio 0.6 mum x 1.5 mum waveguide apertures to inject the light into the input combiner and to intercept different spectral channels at the output combiner focal region. The measured crosstalk is <-10 dB, the 3 dB channel bandwidth is 0.15 nm, and the insertion loss is -17 dB near the central wavelength of lambda = 1.545 mum.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cheben et al. (2007) studied this question.