January 1, 2000IEEE Transactions on Industrial Electronics471 citations

The detection of inter-turn short circuits in the stator windings of operating motors

View Full Paper
GJGojko JoksimovićJPJ. Penman

Key Points

Key points are not available for this paper at this time.

Abstract

This paper develops a winding-function-based method for modeling polyphase cage induction motors with inter-turn short circuits in the machine stator winding. Analytical consideration which sheds light on some components of the stator current spectra of both healthy and faulty machines is developed. It is shown that, as a result of the nature of the cage rotor, no new frequency components of the line current spectra can appear as a consequence of the fault. Only a rise in some of the frequency components which already exist in the line current spectra of a healthy machine can be observed. An experimental setup comprising a 3 kW delta-connected motor loaded by a generator was used to validate this approach. The experimental results obtained clearly validate the analytical and simulation results.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Joksimović et al. (2000) studied this question.

synapsesocial.com/papers/6a7506dd1646b2abe5034b88https://doi.org/10.1109/41.873216