A robust, sensitive, and reliable method was developed and validated on HPLC for the simultaneous estimation of Finerenone (FNR) and Canagliflozin (CFZ). The resolution was performed by using mobile-phase acetonitrile (ACN): Water (51:49) at a flow rate of 0.75 ml/min with the C18 analytical column Phenomenex Luna (250 mm, 4.6 mm, 5 µm). FNR and CFZ were estimated at a retention time of 6.33 and 8.26 min with 10.0 min analysis run time and detected by PDA detector at a λmax 249 and 290 nm, respectively. The calibration curve was linear over the concentration range of 0.05-10 µg/ml with R2 0.998 and 0.999 for FNR and CFZ, respectively. For FNR and CFZ, the limit of detection (LOD) was 0.53 and 0.36 μg/ml & limit of quantitation (LOQ) was 1.62 and 1.10 μg/ml, respectively. The method was validated using specificity, linearity, accuracy, precision, LOD, LOQ, robustness, and stability. According to the International Council for Harmonisation (ICH) guideline, the validation studies confirmed that the optimization method is specific, simple, highly sensitive, reliable, robust, and reproducible. The developed method was successfully applied for simultaneous estimation with applications in in-vitro metabolic stability studies of pooled microsomes of humans, monkeys, dogs, rabbits, rats and mice.
Rathaur et al. (Mon,) studied this question.