To ensure the safety and structural integrity of composite flexible blades under strong winds, this study investigates the extreme aeroelastic responses of the IEA 15 MW wind turbine blade during an emergency shutdown with pitch system faults. Existing studies often rely on simplified models or one-way coupling; we adopt a bidirectional computational fluid dynamics–finite element method (CFD–FEM) fluid–structure interaction (FSI) framework to examine how wind speed and pitch system faults affect aerodynamic loads, displacement responses, and structural stresses when the blade is shut down in a parked-upwind condition. The results reveal that, under the no-pitch condition, the blade experiences extreme loading, with thrust being approximately 15 times higher and the peak stress being 8.6 times that of the pitch condition. Furthermore, a high frequency of 1.969 Hz emerges, significantly increasing the risk of aeroelastic instability as the wind speed increases or under the no-pitch condition. A stress analysis identified that high stress is mainly located in the main spar region, with the peak stress location shifting closer to the blade root under the no-pitch condition. This study highlights the potential risks of composite flexible blades during shutdowns and provides a reference for structural safety design and targeted monitoring.
Wang et al. (Mon,) studied this question.