February 2, 2017Journal of the American Heart AssociationOpen Access

Each 1-hour increase in device-detected daily physical activity was associated with a reduced adjusted odds of frailty (OR 0.71; 95% CI 0.51-0.99) in patients with cardiac implantable devices.

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does device-detected physical activity correlate with frailty and mobility in outpatients with cardiac implantable electrical devices?

Population

219 outpatients with cardiac implantable electrical devices compatible with physical activity analysis with…

Design

Cross-sectional

Key result

Each 1-hour increase in device-detected daily physical activity was associated with a reduced adjusted odds of frailty (OR 0.71; 95% CI 0.51-0.99) in patients with cardiac implantable devices.

Authors

DKDaniel B. KramerTTTimothy TsaiPNPoorna Natarajan

Discussion

Loading...

Member takes

Overview

Supports device activity for frailty screening in CIED patients; leaves open prospective validation before clinical adoption.

Study Design

Type

Observational (n=219)

Structured PICO

Does device-detected physical activity correlate with frailty and mobility in outpatients with cardiac implantable electrical devices?

P
Population
219 outpatients with cardiac implantable electrical devices compatible with physical activity analysis with at least 7 days of data
I
Intervention
Device-detected physical activity measurement
O
Outcome
Association between device-detected physical activity and frailty (Study of Osteoporotic Fractures instrument) and mobility (gait speed, Timed Up and Go test)surrogate

Main Result

Effect estimate: OR 0.71 (95% CI 0.51-0.99)

Device-detected physical activity from cardiac implantable electrical devices correlates significantly with clinical frailty and mobility limitations, offering a potential automated tool for frailty assessment.

Cite This Study

Kramer et al. (2017) conducted an observational in Cardiac implantable electrical devices (n=219). Device-detected physical activity was evaluated on Frailty phenotype (OR 0.71, 95% CI 0.51-0.99). Each 1-hour increase in device-detected daily physical activity was associated with a reduced adjusted odds of frailty (OR 0.71; 95% CI 0.51-0.99) in patients with cardiac implantable devices.

synapsesocial.com/papers/6a1106f5c56c5252651a0b0bhttps://doi.org/10.1161/jaha.116.004659