PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 25, 2011Catheterization and Cardiovascular Interventions28 citations

Transaortic transcatheter aortic valve implantation within a previous bioprosthetic aortic valve replacement

View Full Paper
JCJames CockburnUTUday TrivediDHDavid Hildick‐Smith

Key Result

Transaortic TAVI using a CoreValve prosthesis was successfully performed in a patient with severe bioprosthetic aortic stenosis, reducing peak gradient to 30 mmHg and increasing EOA to 1.5 cm2.

Key Points

  • To report the successful transaortic implantation of a CoreValve prosthesis in a patient with prior bioprosthetic aortic valve replacement.
  • Case report of an 81-year-old woman with severe bioprosthetic aortic valve stenosis
  • Transaortic access via a mini thoracotomy in the left anterior second intercostal space
  • Post-procedure echocardiography and clinical monitoring for outcomes.
  • Post-implantation peak instantaneous gradient reduced from 99 mmHg to 30 mmHg
  • Effective valve orifice area increased from 0.3 cm² to 1.5 cm²
  • Patient discharged on the third post-procedural day with sinus rhythm.

Study Design

Type

Case Report (n=1)

PICO

P
Population
An 81-year-old woman with severe bioprosthetic aortic valve stenosis and no peripheral arterial access options who underwent transaortic TAVI.
I
Intervention / Comparator
Transaortic transcatheter aortic valve implantation (TAVI) using CoreValve
O
Primary Outcome
Procedural success and valve hemodynamics

Abstract

This report documents the first reported case of transaortic transcatheter aortic valve implantation (TAVI) using the CoreValve ReValving system (Medtronic CoreValve System, Luxembourg), within a previous bioprosthetic aortic valve replacement. TAVI has become a recognized percutaneous treatment for patients with severe native or bioprosthetic aortic valve stenosis. However, as the number of patients screened for TAVI increases, a number of patients are found with absolutely no option for peripheral arterial access, either from the femoral or subclavian routes. Transaortic CoreValve placement offers an alternate minimally invasive hybrid surgical/interventional technique when peripheral access is not possible. A CoreValve prosthesis was implanted via the transaortic route in an 81-year-old woman with severe bioprosthetic aortic valve stenosis (21 mm Mitroflow pericardial valve, peak instantaneous gradient of 99 mmHg, effective valve orifice area (EOA) of 0.3 cm(2) , as ilio-femoral and left subclavian angiography revealed small calibre vessels (<6 mm). Access was achieved via a mini thoracotomy via the left anterior second intercostal space. The procedure went without complication. Post procedure the patient was transferred directly to the Cardiac Care Unit for recuperation. Post procedure echocardiography showed that the TAVI was well positioned with no para-valvular leak and a reduction in peak instantaneous gradient to 30 mmHg and an increase in EOA to 1.5 cm(2) . She was discharged on the third post-procedural day in sinus rhythm with a narrow QRS complex. CoreValve implantation within previous surgical bioprosthesis is now an established treatment. The transaortic approach to transcatheter implantation is a promising recent development, when due to anatomical reasons, transfemoral or subclavian TAVI is not feasible.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cockburn et al. (2011) conducted a case report in Severe bioprosthetic aortic valve stenosis (n=1). Transaortic transcatheter aortic valve implantation (TAVI) using CoreValve was evaluated on Procedural success and valve hemodynamics. Transaortic TAVI using a CoreValve prosthesis was successfully performed in a patient with severe bioprosthetic aortic stenosis, reducing peak gradient to 30 mmHg and increasing EOA to 1.5 cm2.