T wave alternans magnitude increased significantly with heart rate, from 0.4 microV in sinus rhythm to 2.4 microV at 120 beats/min (P<0.001), and its diagnostic performance was rate-dependent.
Observational (n=45)
Does heart rate affect the magnitude and diagnostic performance of T wave alternans for inducible ventricular tachycardia in patients undergoing electrophysiologic study?
T wave alternans magnitude and diagnostic performance for inducible ventricular tachycardia are strongly dependent on heart rate, suggesting optimal measurement between 100 and 120 beats/min.
p-value: p=<0.001
INTRODUCTION: T wave alternans (TWA) is a promising technique for detecting arrhythmia vulnerability. Previous studies in animals demonstrated that the magnitude of TWA is dependent on heart rate. However, the effects of heart rate on TWA in humans and the clinical relevance of this effect remain controversial. METHODS AND RESULTS: This was a prospective evaluation of pacing rate and monitoring lead configuration on TWA in subjects undergoing electrophysiologic study. Measurements of TWA were performed on 45 patients in the absence of antiarrhythmic drugs. Recordings were made in normal sinus rhythm and during atrial pacing at 100 and 120 beats/min. Sustained monomorphic ventricular tachycardia (VT) was induced in 29 patients with programmed stimulation. TWA in the vector magnitude lead increased with heart rate, independent of VT inducibility (0.4 +/- 0.7 microV, 1.6 +/- 1.9 microV, and 2.4 +/- 2.1 microV in sinus rhythm and at 100 and at 120 beats/min, respectively; P < 0.001). In addition, the diagnostic performance of TWA for inducible VT was dependent on heart rate (sensitivity 4%, 42%, and 65%, and specificity 100%, 93%, and 63% at 77, 100, and 120 beats/min, respectively). By analyzing orthogonal leads rather than the vector magnitude lead, the sensitivity is increased from 42% to 59% at 100 beats/min, but the specificity is reduced from 93% to 72%. CONCLUSION: These results indicate that TWA in humans is strongly dependent on heart rate with regard to both magnitude and diagnostic performance. The optimal heart rate for the measurement of TWA is between 100 and 120 beats/min and multiple leads should be monitored.
Kavesh et al. (Wed,) conducted a observational in Undergoing electrophysiologic study (n=45). Increased heart rate via atrial pacing vs. Normal sinus rhythm was evaluated on T wave alternans magnitude in the vector magnitude lead (p=<0.001). T wave alternans magnitude increased significantly with heart rate, from 0.4 microV in sinus rhythm to 2.4 microV at 120 beats/min (P<0.001), and its diagnostic performance was rate-dependent.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: