Hypertensive patients had significantly reduced carotid arterial compliance compared with normotensive subjects (5.9 vs. 16.6 10(-7) m2/kPa, P < 0.001).
Cross-Sectional (n=39)
Hypertension (n=39)
Hypertension vs Normotensive subjects
Carotid arterial compliance (10(-7) m2/kPa), p=< 0.001
Absolute Event Rate: 5.9% vs 16.6%
p-value: p=< 0.001
The objectives of this study were to determine whether carotid arterial compliance is reduced in patients with hypertension and to assess whether reduced arterial compliance is related to abnormal arterial baroreflex function. Accordingly, concurrent measurements of carotid arterial diameter (via computerized high resolution B-mode ultrasonography) and blood pressure were made to determine carotid arterial compliance in 23 normotensive and 16 age-matched hypertensive patients. In addition, arterial baroreflex function was assessed in 12 of the normal subjects and nine of the hypertensive patients by measuring the infusions of nitroprusside and phenylephrine. Compared with the normotensive subjects, the patients with hypertension had reduced compliance (5.9 +/- 0.7 vs. 16.6 +/- 1.8 10(-7) m2/kPa, mean +/- SE, P < 0.001). The baroreflex slope relating the change in R-R interval to the change in systolic blood pressure during the drug infusions was less in the hypertensive than normotensive subjects (12.3 +/- 2 vs. 18.9 +/- 2 ms/mmHg, P < 0.05). Consequently, when both normotensive and hypertensive subjects were considered, there was a significant correlation between the baroreflex slope and compliance (r = 0.53, P < 0.05). However, there was no correlation between the baroreflex slope and compliance within either the normotensive group (r = 0.04, P = NS) or the hypertensive group (r = 0.43, P = NS) when analyzed separately. There was a significant correlation between age and compliance (r = -0.48, P < 0.01) but not between age and baroreflex function.(ABSTRACT TRUNCATED AT 250 WORDS)
Building similarity graph...
Analyzing shared references across papers
Loading...
Silvia G. Lage
Universidade de São Paulo
Joseph F. Polak
Boston University
Daniel H. O’Leary
Cardiac Imaging
AJP Heart and Circulatory Physiology
Harvard University
Brigham and Women's Hospital
Building similarity graph...
Analyzing shared references across papers
Loading...
Lage et al. (Thu,) conducted a cross-sectional in Hypertension (n=39). Hypertension vs. Normotensive subjects was evaluated on Carotid arterial compliance (10(-7) m2/kPa) (p=< 0.001). Hypertensive patients had significantly reduced carotid arterial compliance compared with normotensive subjects (5.9 vs. 16.6 10(-7) m2/kPa, P < 0.001).
synapsesocial.com/papers/6a0f3427f7e1df59726c97c4 — DOI: https://doi.org/10.1152/ajpheart.1993.265.1.h232
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: