In this paper, the authors proposed a novel maximum power point controller, which not only can track the maximum power of an array quickly without perturbation and observation process but also can be implemented easily. The main idea is based on the graphical interpretation of the maximum power point as the intersecting point of two curves on the phase plane corresponding to the solution of two algebraic equations. In other words, the operating point is the intersecting point of the PV-array characteristic curve and the maximum power line. A circuit is constructed based on a boost circuit and a three phase full bridge inverter.