Adequate plasma levels of antiarrhythmic agents were associated with protection against recurrent cardiac arrest (p<0.01), despite failing to predictably suppress ventricular ectopic depolarizations.
Observational (n=16)
Survivors of prehospital cardiac arrest (n=16)
Membrane-active antiarrhythmic agents vs Subtherapeutic or unstable plasma levels (Dose-adjusted, plasma level-monitored)
Recurrent cardiac arrest based on plasma level stability, p=<0.01
p-value: p=<0.01
We studied the long-term effects of membrane-active antiarrhythmic agents on chronic ventricular arrhythmias in patients who have survived prehospital cardiac arrest. Among 16 patients treated with a dose-adjusted, plasma level-monitored antiarrhythmic regimen, eight have survived for longer than 12 months and eight have had recurrent cardiac arrests (RCAs). Monthly Holter monitor tapes (HM) recorded during the 4 months before the eight RCAs were compared with monthly HM tapes matched for time of entry and duration of follow-up in the eight patients who did not have RCAs. Transient or persistent complex ventricular ectopic depolarizations (VEDs) have been recorded on 47 of the 63 monthly HM tapes (75%). The difference between VEDs in the RCA patients (mean 153 VEDs/hr, median 19 VEDs/hr) and VEDs in the patients who have not had RCA (mean 122 VEDs/hr, median 8 VEDs/hr) was not significant (p less than 0.2); nor was there a predictable relationship between therapeutic plasma levels of antiarrhythmic agents and the frequency and complexity of chronic asymptomatic VEDs (therapeutic levels--mean 104 VEDs/hr, median 6 VEDs/hr; subtherapeutic levels--mean 184 VEDs/hr, median 21 VEDs/hr). Differences were not significant (p greater than 0.1). In contrast, all eight RCA patients had unstable plasma levels (21 of 31 determinations subtherapeutic) while six of the eight patients who have not had RCA had consistently therapeutic levels (p less than 0.01). Thus, adequate plasma levels of antiarrhythmic agents may protect against RCA, despite failure to suppress VEDs predictably. The apparent dissociation between predictable suppression of chronic VEDs and protection against RCA suggests that clinical effectiveness of these agents may not be best measured by their effect on chronic VEDs.
Building similarity graph...
Analyzing shared references across papers
Loading...
Robert J. Myerburg
Electrophysiology
Cesar A. Conde
Industrial University of Santander
David S. Sheps
Preventive Cardiology
Circulation
Clínica Las Condes
Fundación Universitaria Juan de Castellanos
Building similarity graph...
Analyzing shared references across papers
Loading...
Myerburg et al. (Tue,) conducted a observational in Survivors of prehospital cardiac arrest (n=16). Membrane-active antiarrhythmic agents vs. Subtherapeutic or unstable plasma levels was evaluated on Recurrent cardiac arrest based on plasma level stability (p=<0.01). Adequate plasma levels of antiarrhythmic agents were associated with protection against recurrent cardiac arrest (p<0.01), despite failing to predictably suppress ventricular ectopic depolarizations.
synapsesocial.com/papers/6a0e9dfd53f874f2b2228f6d — DOI: https://doi.org/10.1161/01.cir.59.5.855
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: