Key points are not available for this paper at this time.
This paper outlines an approach to the monitoring of electrical drives by the method of axial flux sensing. It is shown that it is possible to detect a variety of faults using a single noninvasive sensor. A prototype system design incorporating several novel features is also discussed, and experimental results presented.
Penman et al. (1986) studied this question.