In this letter, a genetic algorithm (GA) optimization technique is applied to determine the switching angles for a cascaded multilevel inverter which eliminates specified higher order harmonics while maintaining the required fundamental voltage. This technique can be applied to multilevel inverters with any number of levels. As an example, in this paper a seven-level inverter is considered, and the optimum switching angles are calculated offline to eliminate the fifth and seventh harmonics. These angles are then used in an experimental setup to validate the results.
Ozpineci et al. (Thu,) studied this question.