Aortic valve replacement using frozen irradiated homografts had 8.8% early mortality, 49.6% late mortality over 5-18 years, and a 40% re-operation rate for homograft failure.
Observational (n=307)
No
What are the long-term mortality and re-operation rates following isolated aortic valve replacement with frozen irradiated homografts?
Long-term follow-up of frozen irradiated homografts for aortic valve replacement reveals high rates of late mortality and homograft failure requiring re-operation.
Between May 1968 and April 1981, 339 patients underwent isolated aortic valve replacement using frozen irradiated homografts. All the operations were carried out by the same surgeon (EJMW) using the same technique. Thirty-two patients were lost to follow-up at various stages and the long-term results of the remaining 307 patients are reported. Two hundred and thirty-four were males and 73 females. Their ages ranged between 10 and 75 years, with a mean age of 53. The dominant lesion was aortic stenosis in 195 cases (63.5%), aortic regurgitation in 68 (22.1%), and mixed aortic valve disease in 44 (14.3%). Early mortality was 8.8% and late mortality during the 5-18 year follow-up period was 49.6%. Re-operations for homograft failure were carried out in 112 patients (40%), with an early mortality of 25%. The results are compared with those of other major series using antibiotic sterilized homograft valves.
Campalani et al. (1989) conducted an observational in Aortic valve disease (n=307). Frozen irradiated homografts was evaluated on Late mortality. Aortic valve replacement using frozen irradiated homografts had 8.8% early mortality, 49.6% late mortality over 5-18 years, and a 40% re-operation rate for homograft failure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: