Key points are not available for this paper at this time.
The use of a five-channel CI simulation to estimate the intelligibility of individual sentences allowed for the creation of a large number of sentence lists with an equivalent level of difficulty. The results of the validation procedure with CI users found that 29 of 33 lists allowed scores that were not statistically different. However, individual listeners demonstrated considerable variability in performance across lists. This variability was accurately described by the binomial distribution model and was used to estimate the magnitude of change required to achieve statistical significance when comparing scores from one and two lists per condition. Fifteen sentence lists have been included in the AzBio Sentence Test for use in the clinical evaluation of hearing-impaired listeners and CI users. An additional eight sentence lists have been included in the Minimum Speech Test Battery to be distributed by the CI manufacturers for the evaluation of CI candidates.
Spahr et al. (Tue,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: