Key points are not available for this paper at this time.
A method for analysis of 7 alpha-hydroxy-4-cholesten-3-one in plasma is described. Following solid-phase extraction/purification the compound is determined by high-performance liquid chromatography using a UV detector. The median concentration in healthy subjects was 12 ng/ml (range 3-40). The levels were lower in diseases associated with a low bile acid production: extrahepatic cholestasis, less than 1.5 ng/ml (range less than 0.9-3); liver cirrhosis less than 1.5 ng/ml (range less than 0.9-38), and higher in diseases associated with a high bile acid production: cholestyramine treatment, 188 ng/ml (range 54-477); ileal resection 397 ng/ml (range 128-750). The levels were essentially normal in patients with colon resection. The results are consistent with a strong positive correlation between the levels of 7 alpha-hydroxy-4-cholesten-3-one in plasma and the rate of bile acid synthesis.
Building similarity graph...
Analyzing shared references across papers
Loading...
M. Axelson
Aly A
Jan Sjövall
FEBS Letters
Karolinska Institutet
Karolinska University Hospital
Building similarity graph...
Analyzing shared references across papers
Loading...
Axelson et al. (Mon,) studied this question.
synapsesocial.com/papers/6a1e75db378044768a95306f — DOI: https://doi.org/10.1016/0014-5793(88)80944-x