Key points are not available for this paper at this time.
The performance characteristics of both AMH and AFC for the prediction of ovarian response to exogenous gonadotrophins have been inflated by single site observational cohorts, resulting in the viewpoint that AMH and AFC exhibit equivalent performance characteristics. Large scale multicentre RCTs, with centralized assay performance, have demonstrated that AMH is substantially the more accurate and robust biomarker, probably reflecting difficulties with standardization of AFC determination. While AFC retains some advantages, particularly immediacy and accessibility, international standardization of AMH combined with a stable automated assay is likely to enhance its performance as the biomarker of choice in predicting the ovarian response in assisted conception.
Iliodromiti et al. (Mon,) studied this question.