Continuous infusion of levosimendan yielded a dose-dependent hemodynamic response rate ranging from 50% to 88%, compared with 14% for placebo and 70% for dobutamine (p<=0.001 for dose-response).
RCT (n=151)
Randomized
Double-blind
Yes
Does levosimendan improve hemodynamic parameters in adult patients with NYHA class II-IV heart failure of ischemic origin?
151 adult patients with New York Heart Association class II-IV heart failure of ischemic origin
Levosimendan given as a 10-min intravenous bolus of 3, 6, 12, 24 or 36 microg/kg, followed by a 24-h infusion of 0.05, 0.1, 0.2, 0.4 or 0.6 microg/kg/min
Matching placebo (double-blind) or dobutamine 6 microg/kg/min open-label infusion
Proportion of patients achieving at least one of: 1) >=15% increase in stroke volume at 23 h to 24 h; 2) >=25% decrease in pulmonary capillary wedge pressure (and >=4 mm Hg) at 23 h to 24 h; 3) >=40% increase in cardiac output (with change in heart rate <20%); 4) >=50% decrease in PCWP during two consecutive measurementssurrogate
Levosimendan administered as a bolus followed by a 24-hour infusion produces favorable, dose-dependent hemodynamic improvements in patients with ischemic heart failure.
p-value: p=<=0.001
OBJECTIVES: We sought to define the therapeutic dose range of levosimendan in patients with New York Heart Association class II-IV heart failure of ischemic origin. BACKGROUND: Levosimendan is a calcium sensitizer for treatment of acute decompensated heart failure. METHODS: A double-blind, placebo-controlled, randomized, multicenter, parallel-group study included 151 adult patients. Levosimendan was given as a 10-min intravenous bolus of 3, 6, 12, 24 or 36 microg/kg, followed by a 24-h infusion of 0.05, 0.1, 0.2, 0.4 or 0.6 microg/kg/min, respectively. Dobutamine, for comparative purposes, was given as an open-label infusion (6 microg/kg/min). The primary efficacy variable was the proportion of patients achieving in each treatment group at least one of the following: 1) a > or =15% increase in stroke volume (SV) at 23 h to 24 h; 2) a > or =25% decrease in pulmonary capillary wedge pressure (PCWP) (and > or =4 mm Hg) at 23 h to 24 h; 3) a > or =40% increase in cardiac output (CO) (with change in heart rate HR or =50% decrease in PCWP during two consecutive measurements. RESULTS: The response rate to levosimendan ranged from 50% at the lowest dose to 88% at the highest dose (compared with placebo 14%, dobutamine 70%). A dose-response relationship was demonstrated for levosimendan on increases in CO and SV, and reductions in PCWP during the infusion (for all, p< or =0.001). Headache (9%), nausea (5%) and hypotension (5%) were the most frequently reported adverse events at higher dosages. CONCLUSIONS: Dosing of levosimendan with a 10-min bolus of 6 to 24 microg/kg followed by an infusion of 0.05 to 0.2 microg/kg/min is well tolerated and leads to favorable hemodynamic effects.
Building similarity graph...
Analyzing shared references across papers
Loading...
Markku S. Nieminen
Heart Failure & Transplant
Juha Akkila
Orion Corporation (Finland)
Gerd Hasenfuß
Heart Failure & Transplant
Journal of the American College of Cardiology
University of Helsinki
University Medical Center Utrecht
University of Göttingen
Building similarity graph...
Analyzing shared references across papers
Loading...
Nieminen et al. (Wed,) conducted a rct in New York Heart Association class II-IV heart failure of ischemic origin (n=151). Levosimendan vs. Placebo and open-label dobutamine (6 microg/kg/min) was evaluated on Proportion of patients achieving >=15% increase in SV, >=25% decrease in PCWP, >=40% increase in CO, or >=50% decrease in PCWP (p=<=0.001). Continuous infusion of levosimendan yielded a dose-dependent hemodynamic response rate ranging from 50% to 88%, compared with 14% for placebo and 70% for dobutamine (p<=0.001 for dose-response).
synapsesocial.com/papers/6a07e228e32a1219f49e72fc — DOI: https://doi.org/10.1016/s0735-1097(00)00961-x
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: