A novel doppler probe successfully measured coronary reactive hyperemia in humans, showing a peak to resting velocity ratio of 5.8 ± 0.6 following 20-second coronary occlusions.
Observational (n=13)
Normal coronary arteries (n=13)
Doppler probe measurement of coronary velocity
Ratio of peak to resting velocity following 20 seconds of coronary occlusion
An acceptable method for measuring phasic coronary velocity and reactive hyperemia in humans has not been available. We have developed a doppler probe which can be coupled to surface coronary vessel* at the time of cardiac surgery with a small suction cup. Phasic coronary velocity can be measured with a signal to noise ratio that exceeds 20:1. Animal studies have shown that the probe does not alter myocardial perfusion or cause tissue damage. In addition, changes in mean coronary velocity are closely related (r 0.97) to changes in coronary flow over a wide range (15-400 ml/min). The characteristics of reactive hyperemia in the coronary circulation of dogs determined with the doppler system are similar to those obtained simultaneously with an electromagnetic flow meter. Transient occlusions of branch coronary vessels in patients with normal coronary arteries are not associated with significant changes in heart rate, left atrial, or mean arterial pressure. The characteristics of reactive hyperemia in normal vessels of 13 patients were as follows: although reactive hyperemia responses were demonstrable following 1 to 2-aecond coronary occlusions, maximal responses usually occurred with 20-second coronary occlusions; following 20 seconds of coronary occlusion, the ratio of peak to resting velocity was 5.8 0.6 (mean SE); the ratio of repayment to debt area was 3.1 0.2, and the duration of the reactive hyperemia response was 20.8 0.3 seconds. These studies provide the first quantitative measurements of coronary reactive hyperemia in humans. Circ Res 49: 877878879880881882883884885886887888889890891 1981 Although mean flow to the left ventricle can be assessed in patients with several techniques (Berne and Rubio, 1979;
Building similarity graph...
Analyzing shared references across papers
Loading...
Melvin L. Marcus
Cardiac Imaging
Creighton B. Wright
Mount St. Joseph University
Donald B. Doty
Interventional / Structural Cardiology
Circulation Research
Marcus (United States)
Building similarity graph...
Analyzing shared references across papers
Loading...
Marcus et al. (Thu,) conducted a observational in Normal coronary arteries (n=13). Doppler probe measurement of coronary velocity was evaluated on Ratio of peak to resting velocity following 20 seconds of coronary occlusion. A novel doppler probe successfully measured coronary reactive hyperemia in humans, showing a peak to resting velocity ratio of 5.8 ± 0.6 following 20-second coronary occlusions.
synapsesocial.com/papers/6a0d642748a82a5ce309b6d0 — DOI: https://doi.org/10.1161/01.res.49.4.877
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: