Key points are not available for this paper at this time.
Antibodies against prothrombin are detected by enzyme immunoassays (EIA) in sera of patients with antiphospholipid syndrome (APS). However, there are two methods for antiprothrombin EIA; one that uses high binding plates (aPT-A), and another that utilizes phosphatidylserine bound plates (aPS/PT). We aimed to evaluate and compare aPT-A and aPS/PT in a clinical setting. We performed EIA for anti-PT, anti-PS/PT, IgG, and IgM anticardiolipin antibodies (aCL), and IgG beta2-glycoprotein I-dependent aCL (abeta2GPI/CL) with serum samples from 139 systemic lupus erythematosus (SLE) patients (16 with history of at least one thrombotic episode) and 148 controls. We observed that: (1) although titers of anti-PT and anti-PS/PT were significantly related with each other (P < 0.0001, rho = 0.548), titer of anti-PT and anti-PS/PT differed greatly in some samples; (2) odds ratio and 95% confidence interval for each assay was 3.556 (1.221-10.355) for aPT-A, 4.591 (1.555-15.560) for aPS/PT, 4.204 (1.250-14.148) for IgG aCL, 1.809 (0.354-9.232) for IgM aCL, and 7.246 (2.391-21.966) for abeta2GPI/CL. We conclude that, while all EIA performed in this study except IgM aCL are of potential value in assessing the risk of thrombosis, aPS/PT and abeta2GPI/CL seemed to be highly valuable in clinical practice, and that autoantibodies detected by anti-PT and anti-PS/PT are not completely identical.
Tsutsumi et al. (2006) studied this question.