Irregular biventricular pacing at 120 bpm impaired systolic (dP/dt(max) -8.2%, P<0.001) and diastolic function compared with regular pacing in heart failure patients with AFib, but not at 80 bpm.
Chronic atrial fibrillation, atrioventricular nodal block, and symptomatic heart failure (n=9)
Irregular, Poisson-distributed biventricular pacing vs Regular biventricular pacing at 80 or 120 min(-1) (80 or 120 min(-1) mean rate)
Ventricular systolic (dP/dt(max)) and diastolic function (dP/dt(min), LV end-diastolic pressure), p=<0.001
p-value: p=<0.001
AIMS: Atrial fibrillation (AFib) with a rapid ventricular response may adversely impact cardiac performance, especially in patients with heart failure. However, it remains uncertain whether rhythm irregularity per se has unfavourable effects apart from tachycardia, and whether rate regularization alone can improve heart function. METHODS AND RESULTS: Nine subjects with chronic AFib, atrioventricular nodal block, and symptomatic heart failure (ejection fraction 14-30%) were studied using a pressure-volume catheter. Ventricles were biventricularly paced (RV-apex, LV-lateral wall) at 80 or 120 min(-1) mean rate, using regular or irregular, Poisson-distributed stimulation. At 80 min(-1), ventricular function was similar between the two pacing modes. However, at 120 min(-1), irregular pacing impaired systolic (dP/dt(max): -8.2%, P<0.001) and diastolic function (dP/dt(min): +21%, P<0.001, LV end-diastolic pressure: +26%, P=0.007) compared with regular rate pacing. Contractile function during irregular pacing varied with the ratio of preceding/pre-preceding intercycle (RR) interval (dP/dt(max): 80 b.p.m.: r=0.69; 120 b.p.m.: r=0.74), whereas pre-load had little effect on instantaneous contractility. CONCLUSION: In heart failure subjects with AFib, RR-interval irregularity worsens cardiac function at elevated but not at normal range heart rate. Overall rate control is most important in these patients while rate regularization of rapid AFib may impart additional benefits.
Building similarity graph...
Analyzing shared references across papers
Loading...
Vojtěch Melenovský
Heart Failure & Transplant
Ilan Hay
Sheba Medical Center
Barry Fetics
Robin Medical (United States)
European Heart Journal
Johns Hopkins University
Boston Scientific (Netherlands)
Building similarity graph...
Analyzing shared references across papers
Loading...
Melenovský et al. (Mon,) conducted a other in Chronic atrial fibrillation, atrioventricular nodal block, and symptomatic heart failure (n=9). Irregular, Poisson-distributed biventricular pacing vs. Regular biventricular pacing at 80 or 120 min(-1) was evaluated on Ventricular systolic (dP/dt(max)) and diastolic function (dP/dt(min), LV end-diastolic pressure) (p=<0.001). Irregular biventricular pacing at 120 bpm impaired systolic (dP/dt(max) -8.2%, P<0.001) and diastolic function compared with regular pacing in heart failure patients with AFib, but not at 80 bpm.
synapsesocial.com/papers/6a17060dc7240d1a707bea05 — DOI: https://doi.org/10.1093/eurheartj/ehi066
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: