Key points are not available for this paper at this time.
UNLABELLED: We compared the performance of fully automated quantification of attenuation-corrected (AC) and noncorrected (NC) myocardial perfusion SPECT (MPS) with the corresponding performance of experienced readers for detection of coronary artery disease (CAD). METHODS: Rest-stress (99m)Tc-sestamibi MPS studies (n = 995; 650 consecutive cases with coronary angiography and 345 with likelihood of CAD < 5%) were obtained by MPS with AC. The total perfusion deficit (TPD) for AC and NC data was compared with the visual summed stress and rest scores of 2 experienced readers. Visual reads were performed in 4 consecutive steps with the following information progressively revealed: NC data, AC + NC data, computer results, and all clinical information. RESULTS: The diagnostic accuracy of TPD for detection of CAD was similar to both readers (NC: 82% vs. 84%; AC: 86% vs. 85%-87%; P = not significant) with the exception of the second reader when clinical information was used (89%, P < 0.05). The receiver-operating-characteristic area under the curve (ROC AUC) for TPD was significantly better than visual reads for NC (0.91 vs. 0.87 and 0.89, P < 0.01) and AC (0.92 vs. 0.90, P < 0.01), and it was comparable to visual reads incorporating all clinical information. The per-vessel accuracy of TPD was superior to one reader for NC (81% vs. 77%, P < 0.05) and AC (83% vs. 78%, P < 0.05) and equivalent to the second reader (NC, 79%; and AC, 81%). The per-vessel ROC AUC for NC (0.83) and AC (0.84) for TPD was better than that for the first reader (0.78-0.80, P < 0.01) and comparable to that of the second reader (0.82-0.84, P = not significant) for all steps. CONCLUSION: For detection of ≥70% stenoses based on angiographic criteria, a fully automated computer analysis of NC and AC MPS data is equivalent for per-patient and can be superior for per-vessel analysis, when compared with expert analysis.
Building similarity graph...
Analyzing shared references across papers
Loading...
Reza Arsanjani
Yuan Xu
Sean W. Hayes
Journal of Nuclear Medicine
University of California, Los Angeles
Brigham and Women's Hospital
Cedars-Sinai Medical Center
Building similarity graph...
Analyzing shared references across papers
Loading...
Arsanjani et al. (Fri,) studied this question.
www.synapsesocial.com/papers/69f9345e83388279718789cf — DOI: https://doi.org/10.2967/jnumed.112.108969
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: