Key points are not available for this paper at this time.
In this paper we describe a method for retrospective estimation and correction of eddy current (EC)-induced distortions and subject movement in diffusion imaging. In addition a susceptibility-induced field can be supplied and will be incorporated into the calculations in a way that accurately reflects that the two fields (susceptibility- and EC-induced) behave differently in the presence of subject movement. The method is based on registering the individual volumes to a model free prediction of what each volume should look like, thereby enabling its use on high b-value data where the contrast is vastly different in different volumes. In addition we show that the linear EC-model commonly used is insufficient for the data used in the present paper (high spatial and angular resolution data acquired with Stejskal-Tanner gradients on a 3T Siemens Verio, a 3T Siemens Connectome Skyra or a 7T Siemens Magnetome scanner) and that a higher order model performs significantly better. The method is already in extensive practical use and is used by four major projects (the WU-UMinn HCP, the MGH HCP, the UK Biobank and the Whitehall studies) to correct for distortions and subject movement.
Building similarity graph...
Analyzing shared references across papers
Loading...
Jesper Andersson
Stamatios N. Sotiropoulos
NeuroImage
Wellcome Centre for Integrative Neuroimaging
Building similarity graph...
Analyzing shared references across papers
Loading...
Andersson et al. (Sat,) studied this question.
www.synapsesocial.com/papers/69cab3f5741250c02563991e — DOI: https://doi.org/10.1016/j.neuroimage.2015.10.019
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: