Key points are not available for this paper at this time.
In this paper, a novel dead time compensation method is presented that produces inverter output voltages equal to reference voltages. An experimental result is also presented to demonstrate the validity of the proposed method. It shows that the compensation of the dead time is possible up to a sub-microsecond range. Also, the reference voltage can be used as a feedback value, which is essential for sensorless vector control and flux estimation. The method is based on space vector pulsewidth modulation (PWM) strategy and it can be carried out automatically by an inverter controller for initial setup without any extra hardware.
Building similarity graph...
Analyzing shared references across papers
Loading...
Choi et al. (Fri,) studied this question.
www.synapsesocial.com/papers/6a04e078486eb2282b700154 — DOI: https://doi.org/10.1109/63.486169
Jongwoo Choi
Seung‐Ki Sul
IEEE Transactions on Power Electronics
Seoul National University
Building similarity graph...
Analyzing shared references across papers
Loading...
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: