Screening for atrial fibrillation with a hand-held single-lead ECG device during primary care influenza vaccination sessions yielded 1.1% new cases of AF.
Cross-Sectional (n=3,269)
Yes
Does screening with a hand-held single-lead ECG device improve detection of new atrial fibrillation in primary care patients during influenza vaccination?
Opportunistic screening for atrial fibrillation using a single-lead ECG during primary care influenza vaccination is feasible and yields a 1.1% new detection rate.
To assess the yield of screening for atrial fibrillation (AF) with a hand-held single-lead electrocardiogram (ECG) device during influenza vaccination in primary care in the Netherlands. We used the MyDiagnostick to screen for AF in persons who participated in influenza vaccination sessions of ten Dutch primary care practices. In case of suspected AF detection by the stick, the recorded 1-min ECG registrations were analysed by a cardiologist. We scrutinized electronic medical files of the general practitioners to obtain information about the cases screened. Multivariable logistic regression analysis was performed to predict the relation between patient characteristics and a new screen-detected diagnosis of AF. In total, 3269 persons were screened for AF during the influenza vaccination sessions of 10 general practitioner practices. As a result, 37 (1.1%) new cases of AF were detected. Prior transient ischeamic attack or stroke (OR 6.05; 95%CI 1.93–19.0), and age (OR 1.09 per year; 95% CI 1.05–1.14) were independent predictors for such newly screen-detected AF. Of the 37 screen-detected AF cases, 2.7% had a CHA2DS2-VASc of 0, 18.9% a score of 1, and 78.4% a score of 2 or more. The majority needed oral anticoagulant therapy. Screening seems feasible with an easy to use single-lead, hand-held ECG device with automatic AF detection during influenza vaccination in primary care and results in a ‘1-day’ yield of 1.1% new cases of AF. NCT02006524.
Kaasenbrood et al. (Sat,) conducted a cross-sectional in Atrial fibrillation (n=3,269). Screening with hand-held single-lead ECG device (MyDiagnostick) was evaluated on New screen-detected diagnosis of atrial fibrillation. Screening for atrial fibrillation with a hand-held single-lead ECG device during primary care influenza vaccination sessions yielded 1.1% new cases of AF.