Does an anti-Xa directed protocol reduce blood sampling and improve therapeutic range maintenance compared to an ACT protocol in children supported with ECMO?
An anti-Xa-based heparin management protocol for pediatric ECMO is feasible, significantly reduces blood sampling, and improves maintenance of therapeutic anticoagulation levels compared to ACT monitoring.
The optimum heparin monitoring method during extracorporeal membrane oxygenation (ECMO) is unknown. We report a protocol utilizing only anti-factor Xa (anti-Xa) to manage anticoagulation in 22 consecutive ECMO patients. Anti-Xa was monitored with heparin titration every hour until goal 0.4–0.8 IU/ml. Once therapeutic, monitoring was progressively spaced up to every 6 hours. Patients received frequent antithrombin III (ATIII). Extracorporeal membrane oxygenation indications were as follows: 13 cardiorespiratory failures, eight extracorporeal cardiopulmonary resuscitations (ECPRs), and one pulmonary hypertension. Median weight was 4 kg, age 12.5 days, and ECMO duration 88 hours. Survival was 50%. Mean heparin dose was 38 ± 11 unit/kg/hr. Eight patients received no heparin for median 9 hours because of postoperative bleeding. Compared with prior activated clotting time (ACT) protocol, there were 20 fewer blood draws per day to manage anticoagulation, p < 0.001. Only 9% of the anti-Xa levels were outside therapeutic range versus 22% using ACT, p < 0.01. Six patients had bleeding complications, and seven had oxygenator change-out. Change-out was associated with blood product administration and bleeding but not with heparin-free period (p = 0.39). Survival to discharge was higher among those who did not require circuit/oxygenator change-outs, 4/7 versus 7/7 (p < 0.01). Anti-factor Xa-based ECMO heparin management protocol is feasible, decreases blood sampling and heparin infusion adjustments, and does not appear to increase complications.
O’Meara et al. (Tue,) studied this question.