BACKGROUND: The accuracy of step detection in consumer-based wearable activity monitors in older adults with varied ambulatory abilities is not known. METHODS: We assessed the validity of two hip-worn (Fitbit One and Omron HJ-112) and two wrist-worn (Fitbit Flex and Jawbone UP) activity monitors in 99 older adults of varying ambulatory abilities and also included the validity results from the ankle-worn StepWatch as a comparison device. Nonimpaired, impaired (Short Physical Performance Battery Score 11.5% (ICCs < 0.05). CONCLUSIONS: StepWatch, Omron HJ-112, Fitbit One, and Jawbone UP appeared accurate at measuring steps in older adults with nonimpaired and impaired ambulation during a self-paced walking test. StepWatch also appeared accurate at measuring steps in cane-users.
Floegel et al. (Thu,) studied this question.