Electrocardiographic imaging accurately detected electrical dyssynchrony and resynchronization, identifying the latest site of activation to 9.1 ± 0.6 mm compared to epicardial recordings.
Electrical dyssynchrony (n=11)
Electrocardiographic imaging (ECGi) vs Body surface mapping and epicardial sock recordings
Detection of electrical dyssynchrony and site of latest activation
BACKGROUND: Poor identification of electrical dyssynchrony is postulated to be a major factor contributing to the low success rate for cardiac resynchronization therapy. OBJECTIVE: The purpose of this study was to evaluate the sensitivity of body surface mapping and electrocardiographic imaging (ECGi) to detect electrical dyssynchrony noninvasively. METHODS: Langendorff-perfused pig hearts (n = 11) were suspended in a human torso-shaped tank, with left bundle branch block (LBBB) induced through ablation. Recordings were taken simultaneously from a 108-electrode epicardial sock and 128 electrodes embedded in the tank surface during sinus rhythm and ventricular pacing. Computed tomography provided electrode and heart positions in the tank. Epicardial unipolar electrograms were reconstructed from torso potentials using ECGi. Dyssynchrony markers from torso potentials (eg, QRS duration) or ECGi (total activation time, interventricular delay D-LR, and intraventricular markers) were correlated with those recorded from the sock. RESULTS: LBBB was induced (n = 8), and sock-derived activation maps demonstrated interventricular dyssynchrony (D-LR and total activation time) in all cases (P .05). Although ECGi-derived markers were significantly lower than recorded (P < .05), there was a significant strong linear relationship between ECGi and recorded values. ECGi correctly diagnosed electrical dyssynchrony and interventricular resynchronization in all cases. The latest site of activation was identified to 9.1 ± 0.6 mm by ECGi. CONCLUSION: ECGi reliably and accurately detects electrical dyssynchrony, resynchronization by biventricular pacing, and the site of latest activation, providing more information than do body surface potentials.
Building similarity graph...
Analyzing shared references across papers
Loading...
Laura Bear
Université de Bordeaux
Peter Huntjens
Washington University in St. Louis
Richard D. Walton
Université de Bordeaux
Heart Rhythm
Inserm
Amsterdam UMC Location University of Amsterdam
Maastricht University
Building similarity graph...
Analyzing shared references across papers
Loading...
Bear et al. (Thu,) conducted a other in Electrical dyssynchrony (n=11). Electrocardiographic imaging (ECGi) vs. Body surface mapping and epicardial sock recordings was evaluated on Detection of electrical dyssynchrony and site of latest activation. Electrocardiographic imaging accurately detected electrical dyssynchrony and resynchronization, identifying the latest site of activation to 9.1 ± 0.6 mm compared to epicardial recordings.
synapsesocial.com/papers/6a0ec37c1c5e2d2319f9d5aa — DOI: https://doi.org/10.1016/j.hrthm.2018.02.024