Key points are not available for this paper at this time.
OBJECTIVES: To characterize renin in critically ill patients. Renin is fundamental to circulatory homeostasis and could be a useful marker of tissue-perfusion. However, diurnal variation, continuous renal replacement therapy and drug-interference could confound its use in critical care practice. DESIGN: Prospective observational study. SETTING: Single-center, mixed medical-surgical ICU in Europe. PATIENTS: Patients over 18 years old with a baseline estimated glomerular filtration rate greater than 30 mL/min/1.73 m and anticipated ICU stay greater than 24 hours. Informed consent was obtained from the patient or next-of-kin. INTERVENTIONS: Direct plasma renin was measured in samples drawn 6-hourly from arterial catheters in recumbent patients and from extracorporeal continuous renal replacement therapy circuits. Physiologic variables and use of drugs that act on the renin-angiotensin-aldosterone system were recorded prospectively. Routine lactate measurements were used for comparison. MEASUREMENTS AND MAIN RESULTS: One-hundred twelve arterial samples (n = 112) were drawn from 20 patients (65% male; mean ± SD, 60 ± 14 yr old) with septic shock (30%), hemorrhagic shock (15%), cardiogenic shock (20%), or no circulatory shock (35%). The ICU mortality rate was 30%. Renin correlated significantly with urine output (repeated-measures correlation coefficient = -0.29; p = 0.015) and mean arterial blood pressure (repeated-measures correlation coefficient = -0.35; p < 0.001). There was no diurnal variation of renin or significant interaction of renin-angiotensin-aldosterone system drugs with renin in this population. Continuous renal replacement therapy renin removal was negligible (mass clearance ± SD 4% ± 4.3%). There was a significant difference in the rate of change of renin over time between survivors and nonsurvivors (-32 ± 26 μU/timepoint vs +92 ± 57 μU/timepoint p = 0.03; mean ± SEM), but not for lactate (-0.14 ± 0.04 mM/timepoint vs +0.15 ± 0.21 mM/timepoint; p = 0.07). Maximum renin achieved significant prognostic value for ICU mortality (receiver operator curve area under the curve 0.80; p = 0.04), whereas maximum lactate did not (receiver operator curve area under the curve, 0.70; p = 0.17). CONCLUSIONS: In an heterogeneous ICU population, renin measurement was not significantly affected by diurnal variation, continuous renal replacement therapy, or drugs. Renin served as a marker of tissue-perfusion and outperformed lactate as a predictor of ICU mortality.
Building similarity graph...
Analyzing shared references across papers
Loading...
Patrick J. Gleeson
Ilaria Alice Crippa
Wasineenart Mongkolpun
Critical Care Medicine
Université Libre de Bruxelles
Building similarity graph...
Analyzing shared references across papers
Loading...
Gleeson et al. (Wed,) studied this question.
www.synapsesocial.com/papers/69ffc559831589f3542da742 — DOI: https://doi.org/10.1097/ccm.0000000000003544