BACKGROUND: Estimated glomerular filtration (eGFR) results based on serum creatinine are frequently inaccurate with differences against measured GFR (mGFR) often attributed to unmeasured non-functional factors, such as muscle mass. METHODS: DTPA plasma clearance) in 137 kidney transplant recipients. Serum creatinine was measured by isotopic-calibrated enzymatic analysis, converted to eGFR using Chronic Kidney Disease EPIdemiology (CKD-EPI) formula, then unindexed from body surface area. FINDINGS: <0·001). The diagnostic test performance of CKD-EPI eGFR to predict CKD stage 3 (by mGFR) was weakest in cachexia (sensitivity 68·4%) and muscularity (specificity 47·4%, positive predictive value 54·5% for the highest ASMI quartile). INTERPRETATION: Serum creatinine and eGFR are imperfect estimates of true renal function, with systemic errors from muscle mass, tubular secretion, and intrinsic proportional bias; and additional inaccuracy at the extremes of renal function and patient muscularity. Cautious interpretation of eGFR results in the context of body habitus and clinical condition is recommended.
Nankivell et al. (Mon,) studied this question.