Background: Range of motion (ROM) is an important aspect of orthopaedic patient assessment. It can be measured at the knee joint by determining the knee flexion angle (KFA) a patient can achieve at extremes of flexion and extension. As with any measurement, the accuracy and reliability of the method used determine its validity. The consistency of magnetic resonance imaging (MRI) scans as compared to the current gold standard of X-ray remains unknown in terms of KFA evaluation. The aim of this study was to assess and compare the reliability of measuring KFA between X-ray and MRI scans. Methods: This study included 80 patients (94 knees) who had attended a specialist knee clinic due to varying knee pathologies and undergone both X-ray and MRI scans. Lateral and T1-weighted sagittal imaging views (respectively) were used to measure KFA by two trained observers independently at two separate time points, 8 weeks apart. The data was then statistically analysed and intra- and inter-observer reliability calculated using the intraclass correlation coefficient (ICC). Results: 45.6°) in this regard (P=0.182). Conclusions: Both X-ray and MRI allow KFA to be measured with an excellent degree of reliability. However, X-ray measurements were overall superior to that of MRI mainly due to the larger field of view of the visible on-screen image which more readily identifies the anatomical landmarks required to measure KFA.