Key points are not available for this paper at this time.
Background and aimsThe aim of this study was to develop and externally validate a computer-aided detection (CAD) system for the detection and localization of Barrett’s neoplasia and assess its performance compared with that of general endoscopists in a statistically powered multicenter study by using real-time video sequences.MethodsIn phase 1, the hybrid visual geometry group 16-SegNet model was trained by the use of 75,198 images and videos (96 patients) of neoplastic and 1,014,973 images and videos (65 patients) of nonneoplastic Barrett’s esophagus. In phase 2, image-based validation was performed on a separate dataset of 107 images (20 patients) of neoplastic and 364 images (14 patients) of nonneoplastic Barrett’s esophagus. In phase 3 (video-based external validation) we designed a real-time video-based study with 32 videos (32 patients) of neoplastic and 43 videos (43 patients) of nonneoplastic Barrett’s esophagus from 4 European centers to compare the performance of the CAD model with that of 6 nonexpert endoscopists. The primary endpoint was the sensitivity of CAD diagnosis of Barrett’s neoplasia.ResultsIn phase 2, CAD detected Barrett’s neoplasia with sensitivity, specificity, and accuracy of 95.3%, 94.5%, and 94.7%, respectively. In phase 3, the CAD system detected Barrett’s neoplasia with sensitivity, specificity, negative predictive value, and accuracy of 93.8%, 90.7%, 95.1%, and 92.0%, respectively, compared with the endoscopists’ performance of 63.5%, 77.9%, 74.2%, and 71.8%, respectively (P 90% sensitivity for neoplasia detection. This result needs to be validated during real-time endoscopic assessment. The aim of this study was to develop and externally validate a computer-aided detection (CAD) system for the detection and localization of Barrett’s neoplasia and assess its performance compared with that of general endoscopists in a statistically powered multicenter study by using real-time video sequences. In phase 1, the hybrid visual geometry group 16-SegNet model was trained by the use of 75,198 images and videos (96 patients) of neoplastic and 1,014,973 images and videos (65 patients) of nonneoplastic Barrett’s esophagus. In phase 2, image-based validation was performed on a separate dataset of 107 images (20 patients) of neoplastic and 364 images (14 patients) of nonneoplastic Barrett’s esophagus. In phase 3 (video-based external validation) we designed a real-time video-based study with 32 videos (32 patients) of neoplastic and 43 videos (43 patients) of nonneoplastic Barrett’s esophagus from 4 European centers to compare the performance of the CAD model with that of 6 nonexpert endoscopists. The primary endpoint was the sensitivity of CAD diagnosis of Barrett’s neoplasia. In phase 2, CAD detected Barrett’s neoplasia with sensitivity, specificity, and accuracy of 95.3%, 94.5%, and 94.7%, respectively. In phase 3, the CAD system detected Barrett’s neoplasia with sensitivity, specificity, negative predictive value, and accuracy of 93.8%, 90.7%, 95.1%, and 92.0%, respectively, compared with the endoscopists’ performance of 63.5%, 77.9%, 74.2%, and 71.8%, respectively (P 90% sensitivity for neoplasia detection. This result needs to be validated during real-time endoscopic assessment.
Abdelrahim et al. (Sun,) studied this question.